2011 Volvo XC90
Mileage
79,603
Service Date
9/10/2020
Services Performed
- Evacuate and recycle Freon. Recharge with new freon to manufacturers specifications. Install UV leak detecion dye as required. Check for leaks w/UV dye. Check for proper air conditioning operation.
- Perform a visual inspection for leaks. Install pressure gauges. Check high and low pressures and outlet duct temperature. Scan applicable computer systems. Check cooling fan operation. Evacuate and recycle Freon. Recharge with new freon to manufacturers specifications. Install UV leak detecion dye as required. Check for leaks w/UV dye. Check for proper air conditioning operation. **Needed Freon is additional** Freon Recovered:______65_______KG Freon Capacity: ____90_________KG High side pressure:____200________PSI Low side pressure:_____31_______PSI Leak Detected: **Pass** Fail Duct temperature:_____58________F **Needed Freon is additional**
- Replace failed A/C compressor
Will P. gave our service a 5 star review on 9/11/2020